حکومتی لاک ڈاون ختم ہونے کے بعد ہم سارے کسٹمرز کو  سروس دیں گے۔

 
 

SDM320A 100A 230V Single Phase Two Wires kWh Meter In Pakistan

Related image

For more detail (hallroad.org@gmail.com)

Ask price →
eastron
Out of stock
Add to Wishlist Add to comparison list

Description

Application

The SDM220D “with a LCD screen for prefect reading”, SDM220A with an electromechanical register, are used to measure single-phase like residential, utility and Industrial application. The meter measures active energy meter (kWh) with a pulse output. 

General Specifications
Voltage AC (Un) 230V
Voltage Range  176~276V AC
Base Current (Ib)   10A
Max. Current (Imax) 80A
Mini Current (Imin)  0.5A
Starting current  0.4% of Ib
Power consumption  <2W/10VA
Frequency   50/60Hz(±10%)
AC voltage withstand  4KV for 1 minute
Impulse voltage withstand  6KV-1.2uS wavform
Overcurrent withstand  30Imax for 0.01s
Pulse output rate  1000imp/kWh (default)
Display  SDM220D LCD (backlit optional)
SDM220A electromechanical register
Max. Reading  99999.9kWh
Voltage 0.5% of range maximum
Current 0.5% of nominal
Frequency   0.2% of mid-frequency
Power factor 1% of Unity
Active power   1% of range maximum
Reactive power   1% of range maximum
Apparent power  1% of range maximum
Active energy  Class 1 IEC62053-21
Class B EN50470-3
Reactive energy  1% of range maximum
Environment 
Operating temperature   -25℃ to + 55℃
Storage and transportation temperature  -40℃ to +70℃
Reference temperature 23℃±2℃
Relative humidity   0 to 95%, non-condensing
Altitude  up to 2500m
Warm up time  10s
Mechanical Environment M1
Electromagnetic environment E2
Degree of pollution  2

Pulse Output

The meter provides a pulse output, which is passive type. The constant is 1000imp/kWh.

ATTENTION: Pulse output must be fed as shown in the wring diagram below. Scrupulously respect polarities and the connection mode.

Opt0-coupler with potential-free SPST-NO Contact

Contact range: 5~27VDC  Max. current Input: 27mA DC

Mechanics
Din rail dimensions   36x90x62 (WxHxD) DIN 43880
Mounting  DIN rail 35mm
Sealing   IP51 (indoor)
Material Self-extinguishing UL94V-0

Introduction

The Eastron SDM320D/A DIN rail single phase two wire energy meter with S0 pulse output. SDM320D has LCD display, and SDM320A has analog display, based on kWh. The meter is provided with a non-volatile memory system that ensures that the readings are not lost or altered when power off. The meter allows up to 100A direct load in single phase application. It is perfect measuring instruments for AMR system or Energy monitoring and control system.

General Specifications
Voltage AC (Un) 230V
Voltage Range  176~276V AC
Base Current (Ib)   10A
Max. Current (Imax) 100A
Mini Current (Imin)  0.5A
Starting current  0.4% of Ib
Power consumption  <2W/10VA
Frequency   50/60Hz(±10%)
AC voltage withstand  4KV for 1 minute
Impulse voltage withstand  6KV-1.2uS wavform
Overcurrent withstand  30Imax for 0.01s
Pulse output rate 

1600imp/kWh

Display  SDM220D LCD (backlit optional)
SDM220A electromechanical register
Max. Reading  99999.9kWh
Voltage 0.5% of range maximum
Current 0.5% of nominal
Frequency   0.2% of mid-frequency
Power factor 1% of Unity
Active power   1% of range maximum
Reactive power   1% of range maximum
Apparent power  1% of range maximum
Active energy  Class 1 IEC62053-21
Class B EN50470-3
Reactive energy  1% of range maximum
Environment 
Operating temperature   -25℃ to + 55℃
Storage and transportation temperature  -40℃ to +70℃
Reference temperature 23℃±2℃
Relative humidity   0 to 95%, non-condensing
Altitude  up to 2500m
Warm up time  10s
Mechanical Environment M1
Electromagnetic environment E2
Degree of pollution  2

Pulse output

The SDM320D/A DIN rail energy meter is equipped with a pulse output which is fully separated from the inside circuit. That generates pulses in proportion to the measured energy for accuracy testing. 

The pulse output is a polarity dependant, passive transistor output requiring an external voltage source for correct operation. For this external voltage source, the voltage (Ui) should is 5-27V DC, and the maximum input current (Imax) is 27mA DC. To connect the impulse output, connect 5-27V DC to connector 6 (anode), and the signal wire (S) to connector 5 (cathode). The meter pulses is indicated on the front panel.

Reviews